Presentation | A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission critical environments. |
---|---|
Lead time | Usually Ships within 6 Weeks |
Run time for load
W information_stroke
Min-max: 50000-500000 W
|
6min 5s
|
---|---|
Max. Capacity Used
information_stroke
|
100 % |
Main Input Voltage | 480 V 3 phases 400 V 3 phases |
Other Input Voltage | 415 V |
Main Output Voltage | 480 V 3 phases 400 V 3 phases |
Other Output Voltage | 380 V 415 V |
rated power in W | 500000 W |
rated power in VA | 500000 VA |
output connector type | Hard wire 4-wire (3P + E) 1 Hard wire 5-wire (3P + N + E) 1 |
battery type | VRLA |
provided equipment | Assembly service Installation guide Network management card Start-up service User manual |
bypass voltage tolerance | +/- 10 % settable from +/- 4/6/8 and 10 % |
---|---|
Number of power module free slots | 0 |
Number of power module filled slots | 20 |
redundant | Yes |
colour | Black |
---|---|
height | 199.1 cm |
width | 520 cm |
depth | 107 cm |
net weight | 8521 kg |
USB compatible | No |
network frequency | 40…70 Hz auto-sensing |
---|---|
number of input connectors | 1 hard wire 4-wire (3P + E) 1 hard wire 5-wire (3P + N + E) |
input voltage limits | 340…460 V 400 V 408…552 V 480 V |
max short time withstand current | 50 kA |
input harmonic distortion | Less than 5 % for full load |
input protection type | 3-pole circuit breaker |
load power factor | 0.5 leading to 0.5 lagging |
Input Power Factor at Full Load | 0.99 |
Maximum configurable power in W | 500000 W |
---|---|
harmonic distortion | Less than 2 % |
output frequency | 50 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised 60 Hz sync to mains |
UPS type | Double conversion online |
Wave type | Sine wave |
output voltage tolerance | +/- 1% static and +/- 5% at 100% load step |
output harmonic distortion | < 2% linear load and < 3% non-linear load |
output overload operation | 10 minutes at 125% and 60 seconds at 150% |
bypass type | Built-in maintenance bypass Built-in static bypass |
efficiency | 96 % (in battery operation) |
Maximum configurable power in VA | 500000 VA |
Transfer time | 2 ms typical |
product certifications | CUL listed EUROBAT UL listed |
---|---|
standards | CSA C22.2 No 107.3-05 EN/IEC 62040-1-1 EN/IEC 62040-2 EN/IEC 62040-3 OSHPD UL 1778 UL 60950-1 |
ambient air temperature for operation | 0…40 °C |
---|---|
relative humidity | 0…95 % |
operating altitude | 0…3333 ft |
ambient air temperature for storage | -15…40 °C |
storage Relative Humidity | 0…95 % |
storage altitude | 0.00…15240.00 m |
acoustic level | 54 dBA |
heat dissipation | 61893 Btu/h |
NEMA degree of protection | NEMA 1 |
IP degree of protection | IP20 |
Run Time | View Runtime Graph
action_new_window
|
---|---|
Efficiency | View Efficiency Graph
action_new_window
|
number of battery filled slots | 32 |
number of battery free slots | 0 |
Battery recharge time | 3.5 h |
number of battery replacement quantity | 6 |
battery overload operation | 10 minutes at 125% and 60 seconds at 150% |
battery charger power | 47262 W rated |
battery design life | 5…8 year(s) |
Battery power in VAH | 165888 VAh runtime |
battery option | SYBFXR8-8 1 207360 VAh SYBFXR8-8 2 248832 VAh SYBFXR8-8 3 290304 VAh SYBFXR8-8 4 331776 VAh |
extended runtime | 1 |
free slots | 1 |
---|---|
preinstalled device | Network management card 2 with environmental monitoring, out of band access and Modbus |
control panel | Touch screen LCD user interface |
Emergency power off | Optional |
Package 1 Weight | 9314 kg |
---|---|
Package 1 Height | 215 cm |
Package 1 width | 710 cm |
Package 1 Length | 127 cm |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
---|