Wave Power Solutions

GUPXC80H2 GUTOR PXC IEC 80kVA

Enquire Now
Overview
Presentation High performance, compact 3 phase UPS power protection fully standardized for heavy industrial applications and harsh environments. Available in 3:3 and 3:1 configurations.
Lead time Usually Ships within 6 Weeks
Main
Main Input Voltage 400 V 3 phases
Other Input Voltage 400 V
Main Output Voltage 400 V 3 phases
Other Output Voltage 400 V
rated power in W 64000 W
rated power in VA 80000 VA
output connector type Hard wire 5-wire (3P + N + E) 1
battery type External battery system
provided equipment Dust filter
Installation guide
Network management card
User manual
General
bypass wiring configuration 5 wire (3P + N + E)
bypass voltage tolerance +/- 10 %
max bypass input current 128 A
bypass current protection 160 A
Number of power module free slots 0
Number of power module filled slots 0
redundant No
Physical
height 210 cm
width 60 cm
depth 80 cm
net weight 460 kg
mounting preference No preference
mounting mode Not rack-mountable
two post mountable 0
USB compatible No
Input
network frequency 45…65 Hz
number of input connectors 1 hard wire 5-wire (3P + N + E)
input voltage limits 360…440 V 400 V
maximum input current 164 A
switching current capacity 200 A
max short time withstand current 65 kA
input harmonic distortion Less than 5 % for full load
input protection type Upstream protection according to source
input current 164 A per phase (3 phases)
load power factor 0.5 leading to 0.5 lagging without derating
Input Power Factor at Full Load 0.98
Output
Maximum configurable power in W 64000 W
harmonic distortion Less than 5 %
output frequency 50/60 Hz +/- 1 Hz sync to mains
60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
crest factor Unlimited
UPS type Double conversion online
Wave type Sine wave
output voltage tolerance +/- 1 %
output harmonic distortion < 2% at 100% linear load and < 5% at 100% non-linear load
output overload operation 10 minutes at 125% and 60 seconds at 150%
required output current protection 160 A
neutral output current 115 A
bypass type Built-in bypass
efficiency 94.6 % (full load)
94.9 % (half load)
93.9 % (in battery operation)
Maximum configurable power in VA 80000 VA
Conformance
product certifications CE
marking CE Mark
standards IBC 2012
IEC 62040-1-1
IEC 62040-2
IEC 62040-3
ISTA 2B
VFI-SS-111
Environmental
ambient air temperature for operation -10…40 °C
relative humidity 0…95 % non-condensing
operating altitude 0…10000 ft
ambient air temperature for storage -30…70 °C
storage Relative Humidity 0…95 % Non-condensing
storage altitude 0.00…4572.00 m
acoustic level 65 dBA
heat dissipation 12539 Btu/h
IP degree of protection IP42 with air filter
Batteries & Runtime
number of battery filled slots 0
number of battery free slots 0
max current discharge 208 A
Battery power in VAH 0 VAh runtime
extended runtime 0
Communications & Management
free slots 1
preinstalled device Network management card 2 with environmental monitoring, out of band access and Modbus
control panel Multifunction LCD status and control console
alarm Audible and visible alarms prioritized by severity
Emergency power off Yes
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 536.61 kg
Package 1 Height 230.0 cm
Package 1 width 82.0 cm
Package 1 Length 108.2 cm
Contractual warranty
Warranty 1 year on-site repair or replace with factory authorized Start-Up